Search results for "Unbonded cables"

showing 1 items of 1 documents

Influence of axial force and corrosion on failure of prestressed concrete structures considering M-V interaction

2021

Abstract Existing prestressed concrete structures suffer from degradation of prestressing for two main reasons: a defect of the sheath infills (cement grout) of bonded tendons, and corrosion of steel strands. These two causes, often concomitant, lead to a reduction over time of the effectiveness of initial prestressing, in addition to the ordinary tension losses due to concrete shrinkage and creep, and to steel relaxation. In many cases a consequence of bad grouting in bonded tendons is that the structure shows an intermediate behavior between that of external prestressing and that of internal bonded prestressing. This, added to damage to wires due to corrosion, makes it essential for the d…

Materials scienceBendingInteractionPrestressing0211 other engineering and technologiesBonded tendon020101 civil engineering02 engineering and technologyBendingBending; Bonded tendons; Corroded structures; Interaction; Polcevera viaduct; Prestressing; Shear; Unbonded cables0201 civil engineeringDecklaw.inventionCorrosionStress (mechanics)Prestressed concretelawCorroded structure021105 building & constructionCorroded structuresCivil and Structural EngineeringShrinkageTension (physics)business.industryBonded tendonsShearStructural engineeringCreepPolcevera viaductbusinessUnbonded cables
researchProduct